Radiancy FSD+ User Manual Page 102

  • Download
  • Add to my manuals
  • Print
  • Page
    / 109
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 101
Lifvation
http://3dLipoMed.Lifvation.com
Cryo Maintenance
April 15, 2014
LIFVATION, http://www.lifvation.com, all
rights reserved.
102
#
What you are
checking:
Procedure
Frequency
What to record
Troubleshooting
y1
Water Level
Always ensure Water tank is full
and follow the instructions on
the water filling document.
Weekly
Write
down the
check date
y2
Plate
cooling
efficiency
Check that both cooling plates
in the hand sets are chilling
down
Daily
Write down down
time to cool
If heat is experienced
during or prior to a
cryo
treatment, stop
the treatment.
y3
Vacuum
efficiency
Always ensure the filter on the
back of the machine is free of
fluid. Empty immediately if
signs of fluid are present
ensuring that the O ring
remains in place to prevent loss
of vacuum.
Daily
Write down the
check date
y4
Replace Cryo head filter at least
once per month or sooner if
experiencing lack of vacuum.
Monthly
Record the last
replacement date
y5
Vacuum Safety
Always check both emergency
stop buttons are functioning
prior to treatment.
Daily
Write down the
check date
Page view 101

Comments to this Manuals